Tiring friday

0 8
Avatar for technician
2 years ago
Topics: Work

Yet another tiring day , here I share what I and team did in the day

 

LP01 (1900 ~ 2050)                                                           

Mthly PM follow up by Goh. Run 1 lot of conditioning done. Qual,E/r check passed 5377, del 01.75 %  . PAR:11/ & 12/1 counts.                                                    

 

Performed 5S done.Point check. & Tencor check by Engineer pass.                                                

                                                                               

                                                                               

LA1B (2100 ~ 0615)                                                            

It was Down For Max run + SFG s/h change PM Done by Goh.    

                                                             

Process chamber wet clean done. Scrub process chamber with green wool. Upper and lower baffles wet clean done.

                                       

Replaced s/h inner and outer o-ring. Replaced all screws and inserter & SFG silicon electrode. Replaced all ceramic parts                                                    

 

Gap Parallelism check done. Replaced endpoint o-ring. Replaced helium clamp and vespel ring.                                        

 

Closed and pump down chamber & done. Check all parameter done. Gap cal, no adjusted.                                                         

 

Quals:                                                                        

 # L/r :5.00 mt/min                                                            

 # E/r :4523,4429,4500,4539,4530=4504   Delta :110                             

 # Par :10/1 counts                                                            

 

Performed 5'S done & M/C up for prod. 

1
$ 0.74
$ 0.74 from @TheRandomRewarder
Avatar for technician
2 years ago
Topics: Work

Comments